Keypad Access Controller


Type: AR-721 (H)
Name: Keypad Access Controller
Description: Combined to read, control and set.

Frequency125kHz or 13.56MHz
Standard125kHz : EM Standard
13.56MHz : ISO14443A
                     ISO15693(Option)
                     DESFire(Option)
                     PSAM(Option)
                     NFC(Option)
Reading Range125kHz : 10-18cm
13.56MHz : 2-8cm
Power Supply9-16VDC
Power Consumption< 3W
Communication InterfaceRS-485
Data Transfer Rate9600 bps(N,8,1)
Operating Temperature–20? TO +60?
Digital InputEgress(R.T.E.) / Door contact
Relay OutputLock Relay
Lock Relay TimeToggle, 0.1~600 Sec.
Alarm TimeToggle, 1~600 Sec.
Tamper SwitchLimit Switch(Form C)
User CapacityM4 / M8 : 1,024
M6 : 65,000
Event Log1,200
External Reader1 WG Port
Anti-pass-backYes(Only M4/M8)
Lift Control32 Floors, 1,024 Users
Serial PortYes
Real Time ClockYes
LCD PanelNo
Door Bell ButtonNo
Transistor OutputArming LED/ Alarm/ Duress/ Security trigger signal
Protection StandardNo
Indicator1 Bi-Color LED & 1 Beeper
Keypad MaterialRubber
Housing MaterialABS
Time Zone11/63(Connect to Multi-Door Networking Controller
Operation ModeStand-Alone / Networking
ColorGray / Silver
Dimensions(mm)111(L)X77(W)X26(H)
Weight(g)100±10

Features

- RS-485 communication interface
- Supporting WG port for anti-pass-back function
- TTL serial output for various application and lift control
- Selectable working frequencies: 125kHz/ 13.56MHz
- 3 control modes: M4/ M6/ M8
- User capacity: 1,024; Event log: 1,200
- 3 access modes: Card only, Card or PIN, Card and PIN
- Built-in Watchdog to prevent system from hanging
- Built-in Real Time Clock & Anti-Tamper functions
- Including the input of door contact, offering the alarm system of both door opening too long and being forced to open
- Built-in Multi-Output: Door Lock/ Alarm/ Arming/ Duress/ Security trigger signal
- 11 sets of Time Zone for various accessing in network
- 2 sets of Auto-Open Zone editable by stand-alone operation
- Intelligent to shift for stand-alone or networking mode while system disconnected
- Auto-lock of the keypad for 30 seconds after continuous failed operation by 3 times
- Coordinating with softwares for further application on access control, time attendance, payroll, and door/ sensor image-monitor function
- Flexible to integrate with other equipment
- 1 bi-color LED and 1 beeper for identification

Pershkrimi Data e publikimit Shkarko
Catalogue 2 17.06.2014
Manual 17.06.2014
Catalogue 1 17.06.2014