Keypad Access Controller

Type: AR-721 (H)
Name: Keypad Access Controller
Description: Combined to read, control and set.
| Frequency | 125kHz or 13.56MHz |
| Standard | 125kHz : EM Standard 13.56MHz : ISO14443A ISO15693(Option) DESFire(Option) PSAM(Option) NFC(Option) |
| Reading Range | 125kHz : 10-18cm 13.56MHz : 2-8cm |
| Power Supply | 9-16VDC |
| Power Consumption | < 3W |
| Communication Interface | RS-485 |
| Data Transfer Rate | 9600 bps(N,8,1) |
| Operating Temperature | 20? TO +60? |
| Digital Input | Egress(R.T.E.) / Door contact |
| Relay Output | Lock Relay |
| Lock Relay Time | Toggle, 0.1~600 Sec. |
| Alarm Time | Toggle, 1~600 Sec. |
| Tamper Switch | Limit Switch(Form C) |
| User Capacity | M4 / M8 : 1,024 M6 : 65,000 |
| Event Log | 1,200 |
| External Reader | 1 WG Port |
| Anti-pass-back | Yes(Only M4/M8) |
| Lift Control | 32 Floors, 1,024 Users |
| Serial Port | Yes |
| Real Time Clock | Yes |
| LCD Panel | No |
| Door Bell Button | No |
| Transistor Output | Arming LED/ Alarm/ Duress/ Security trigger signal |
| Protection Standard | No |
| Indicator | 1 Bi-Color LED & 1 Beeper |
| Keypad Material | Rubber |
| Housing Material | ABS |
| Time Zone | 11/63(Connect to Multi-Door Networking Controller |
| Operation Mode | Stand-Alone / Networking |
| Color | Gray / Silver |
| Dimensions(mm) | 111(L)X77(W)X26(H) |
| Weight(g) | 100±10 |
Features
- RS-485 communication interface
- Supporting WG port for anti-pass-back function
- TTL serial output for various application and lift control
- Selectable working frequencies: 125kHz/ 13.56MHz
- 3 control modes: M4/ M6/ M8
- User capacity: 1,024; Event log: 1,200
- 3 access modes: Card only, Card or PIN, Card and PIN
- Built-in Watchdog to prevent system from hanging
- Built-in Real Time Clock & Anti-Tamper functions
- Including the input of door contact, offering the alarm system of both door opening too long and being forced to open
- Built-in Multi-Output: Door Lock/ Alarm/ Arming/ Duress/ Security trigger signal
- 11 sets of Time Zone for various accessing in network
- 2 sets of Auto-Open Zone editable by stand-alone operation
- Intelligent to shift for stand-alone or networking mode while system disconnected
- Auto-lock of the keypad for 30 seconds after continuous failed operation by 3 times
- Coordinating with softwares for further application on access control, time attendance, payroll, and door/ sensor image-monitor function
- Flexible to integrate with other equipment
- 1 bi-color LED and 1 beeper for identification